SISMOS-4
Magnetic Field & Vibration Survey System
ITEL portable, high-precision magnetic field and vibration survey system, specifically designed for pre-installation MRI site assessments and other high-sensitivity environments.
Measure First. Decide with Confidence.
Invisible Risks Can Kill an MRI Project
What you don’t measure can cost you everything. MRI systems, electron microscopes and high-precision sensors are extremely sensitive to environmental disturbances.
ENVIRONMENTAL THREATS
Low-frequency magnetic field fluctuations
Environmental electromagnetic interference (EMI)
Mechanical vibrations
Acoustic noise
What you don’t measure can cost you everything. These disturbances are often invisible during standard site inspections.
Low-frequency magnetic field fluctuations
Mechanical vibrations
Environmental electromagnetic interference (EMI)
Acoustic noise
These Disturbances Can Cause
Image Artifacts & Instability
Site Rejection by OEMs
Costly Redesigns & Delays
Post-Installation Mitigation Expenses
In today’s healthcare market, guesswork is not an option.
SISMOS-4 Environmental Survey System
Professional site intelligence before you build or install
SISMOS-4 turns uncertainty into data — and data into decisions. Know if a site is suitable before installation, understand which mitigation is required, and provide engineering-grade data to OEMs and planners.
What it does
Measures low-frequency magnetic field disturbances
Detects vibrations and acoustic noise
Analyzes data in time and frequency domains
Identifies both slow trends and fast transient events
Why it matters
You know if a site is suitable before installation
You understand which mitigation is required (if any)
You provide engineering-grade data to OEMs and planners
Core Benefits
Complete Environmental Assessment
Simultaneous monitoring of magnetic fields and vibrations using a single portable system.
High-Resolution, Engineering-Grade Accuracy
24-bit data acquisition ensures precise detection of even minimal disturbances.
Time & Frequency Domain Analysis
Instant visualization of spectra, RMS and peak-to-peak values for full diagnostic insight.
Designed for MRI & Sensitive Applications
Purpose-built for MRI pre-installation surveys, electron microscopy and precision environments.
Portable & Field-Ready
Battery-powered, lightweight and easy to deploy on site.
System Architecture & Performance
Measurement Channels
- Magnetic Field: 3 channels for triaxial magnetic field sensors
- Vibration/Acoustic: 1 channel for uniaxial accelerometer or acoustic sensor
Data Acquisition
- ADC Resolution: 24-bit
- ADC Type: Delta-Sigma with analog pre-filtering
- Sampling Method: Simultaneous
- Sampling Rate: 1.652 kS/s to 51.2 kS/s
Frequency Analysis
- Spectrum: RMS, Peak-to-Peak
- Power Spectral Density: RMS/√Hz, p-p/√Hz
Electrical & Signal Performance
- Input Voltage Range: ±10 V
- Input Coupling: AC / DC selectable via software
- AC Filter Cutoff: 0.5 Hz (-3 dB), 4.6 Hz (0.1 dB max)
- Crosstalk (1 kHz): –110 dB
- Input Impedance: 1 MΩ (magnetic field sensor)
- Phase Error: Fin × 0.045° + 0.04° max
Supplied Accessories
- Fluxgate sensor
- Accelerometer
- USB cable for connected PC
- Power cable
- Tripod and adapter for Fluxgate Sensor
- Accelerometer base
- SiSMoS-4 User Manual
- Hard carrying case
Certifications
- IEC EN 61326-1:2013
- IEC EN 61010-1:2013
- EMC Directive 2014/30/EU
- LVD Directive 2014/35/EU
- RoHS & WEEE compliant
Complete Specifications
Start Every MRI Project with the Right Data
Contact ITEL Healthcare USA Today
Phone: +1 646 6809671
Request a SISMOS-4 Site Survey
Speak with a Field Measurement Expert and plan your MRI installation with confidence.